      HM22 High - accuracy Pressure Transducer

      Description

      HM22 High - accuracy pressure transducer is a new pressure transducer jointly developed, researched, and produced by us and German HELM Company. HM22 High - accuracy pressure transducer is designed with Germany made high–accuracy force–sensitive chip as a central sensing and measuring element, using such new high technology as temperature automatic compensation and normalized circuit commissioning etc. to greatly enhance overall accuracy of the product. This product is designed with advanced technology, superior performance, reliable quality, and small dimension, which may widely be used for such scientific research and production fields as airspace and aerospace, petroleum, chemical, metallurgical and electric power, building material, hydrographic and geographic, medical, protection of environment etc. It may realize high–accuracy measurement of fluid pressure and liquid level.

      Features of Product

      ☆ Designed with Germany made high–accuracy force–sensitive chip as a central sensing and measuring element, with a accuracy up to 0.1% FS 

      ☆ Designed with sensor temperature automatic compensation and normalized circuit commissioning to enhance temperature stability indicator up to 0.1% FS / ℃. 

      ☆ May measure corrosive and easily crystalline medium under special requirements 

      ☆ Designed with fully enclosed structure, all structural members made of stainless steel, which may be used in the open air for a long time. 

      ☆ May be used for the site with online temperature measuring for a long time and without calibration. 

      ☆ May be used for hazardous site, with intrinsically safe type Ex ia II CT5 

      ☆ Structural diversification, design may be customized at the customer’s special requirements.


      Application of Product

      Details

      Measuring range

      -100KPa ~ 0 ~ 5KPa … 100MPa

      Permissible over    pressure

      Two times of    full–scale pressure (where 1.1 times of    full–scale pressure for the 100MPa product.

      Type of pressure

      Gauge pressure or    absolute pressure

      Medium to be measured

      The gas or liquid    compatible with 316 stainless steel ,

      Overall accuracy
                 (Non-linear, repeatability,    lagging)

       ± 0.1% FS 

       ± 0.25% FS

      Long-term stability

      Typical:  ± 0.1% FS / year      

      Maximum:  ± 0.2% FS / year

      Zero point temperature    drifting

      Typical:  ± 0.01% FS / ℃

      Maximum: ± 0.15% FS / ℃

      Sensitivity    temperature drifting

      Typical:  ± 0.01% FS / ℃

      Maximum: ± 0.15% FS / ℃

      Working temperature

      -20~85℃

      Compensating    temperature

      -20~60℃

      Ambient temperature

      -40~85℃

      Range of power    supplying

      12 ~ 36V DC( generally    24V DC)

      Signal output

      4~20mA / 1-5V DC / 0~5V DC / 0.5~4.5V DC

      Load resistance

      ≤(U - 12) / 0.02Ω

      Enclosure Protection degree

      Plug type (IP65); cable type (IP67)

      Safe explosion–proof

      Ex ia II CT5

      Tolerance of vibration

      ≤ ± 0.01% FS(Axles X, Y,    and Z, 200Hz / g) 

      Response time

      ≤2ms

      Thermal lagging

       ± 0.1% FS (typical)

      Insulation resistance

      100MΩ, 500V DC

      Weight

      Approx. 250g

      Product selection


                 HM22

      High - accuracy Pressure Transducer

       

      Guideline of Selection

      High - accuracy Pressure Transducer

       

      Type of pressure

      Gauge pressure (G, may not be indicated); absolute pressure (A)

       

       

      Range

      Measuring Range

       

       

      0 ~ X KPa or 0 ~ X KPa

       

       

       

       

       

      Code

      Overall accuracy (linear + repeatability + lagging)

       

       

       

       

       

      2

       ± 0.25% FS

       

       

       

       

       

      3

       ± 0.1% FS

       

       

       

       

       

       

       

      Code

      Signal Output

       

       

       

       

       

       

       

      A1

      4 ~ 20mA

       

       

       

       

       

       

       

      V1

      1 ~ 5V DC

       

       

       

       

       

       

       

      V2

      0 ~ 5V DC

       

       

       

       

       

       

       

      V3

      0.5 ~ 4.5V DC

       

       

       

       

       

       

       

       

       

      Code 

      Additional functions

       

       

       

       

       

       

       

       

       

      F1

      M20 x 1.5 external thread

       

       

       

       

       

       

       

       

       

      F2

      G 1 / 4 external thread

       

       

       

       

       

       

       

       

       

      F0

      Special

       

       

       

       

       

       

       

       

       

      W1

      Cable type (IP67, 2m)

       

       

       

       

       

       

       

       

       

      W2

      Socket type (IP65, DIN3650)

       

       

       

       

       

       

       

       

       

      P

      Flushed membrane type

       

       

       

       

       

       

       

       

       

      E

      Intrinsically safe explosion - proof type Ex ia II CT5

       

       

       

       

       

       

       

       

       

       

       

       

      HM22 ( 0 ~ 10KPa)

       

       

      — 3

      — A1

      — F1

      — W2 High - accuracy Pressure Transducer


      Tips of Selection

      1. The medium to be measured shall be compatible with the material contacting with the product.
      2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
      3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.


      bottom-nav_01.png

      主要產品:
      HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |
      三级黄色日本三级欧美三级黄色片,西西人体做爱视频,免费人成视频在线播放,在线免费成年片A