      HM20 General - type Pressure Transducer Description

      Description

      HM20 General - type pressure transducer is produced with proprietary technology, adopting imported silicon sensitive elements as well as normalized designed circuits and assembling technology to ensure product progressiveness, practical use, and quality stability. This standard product may widely be used for all kinds of application. Our design team, under the precondition ensuring quantity and application, may re-design or improve to meet special requirements of application at the user’s specific requests.

      Features of Product

      ☆  High ratio of performance to costs 

      ☆ Designed with silicon sensitive elements imported from Germany, with excellent corrosion -, impact -, overloading -, vibration -, and wear–performance. 

      ☆  Wide range of operating temperature, high overall measuring accuracy, and good long–term stability 

      ☆  Normalized design and production ensures product progressiveness, practical use, and quality stability 

      ☆  Wide range of scale: From vacuum to 100MPa and designed with positive and negative gauge pressure range

      Application of Product

       ☆ Internal combustion engine 

       ☆ Air–conditioner and chilling equipment 

       ☆  Testing bench 

       ☆  Hydraulic and pneumatic system 

       ☆  Engineering machinery 

       ☆ Energy and water treatment system 

       ☆ Agricultural mechanical equipment 

       ☆ Locomotive braking system 

       ☆  Medical equipment     

       ☆  Pump and compressor 

       ☆  Equipment automation

      Details

      Technical Data 

      Measuring range

      -100kPa ~ 0 ~ 5KPa … 100MPa

      Overloading capacity

      Two times of FS pressure (where over pressure for 100MPa is designed    with 1.1 times of FS pressure)

      Pressure type

      Gauge pressure or absolute pressure

      Medium to be measured

      The gas or liquid compatible with 316 stainless steel

      Overall accuracy
                 (Linear, repeatability,    lagging)

       ± 0.25% FS

       ± 0.4% FS

      Long-term stability

      Typical: ± 0.1% FS

      Maximum: ± 0.2% FS

      Zero point temperature drifting

      Typical: ± 0.2% FS

      Maximum: ± 0.05% FS / ℃

      Sensitivity temperature drifting

      Typical: ± 0.2% FS

      Maximum: ± 0.05% FS /  ℃

      Operating temperature

      -40 ~ +85 ℃

      Compensating temperature

      -10 ~ +60 ℃

      Range of power supplying

      12 ~ 36V DC (24V DC generally)

      Signal output

      4  ~ 20mA / 1    ~ 5V DC / 0 ~ 5V DC / 0.5 ~ 4.5V DC

      Load resistance

      ≤ (U-12) / 0.02Ω

      Enclosure protection degree

      IP 67 (Cable Type)  IP 65 (Socket    Type)

      Safe explosion - proof

      Ex ia II CT5

      Weight

      Approx. 0.5kg

      Vibrating tolerance

      ≤ ± 0.01% FS ( Axles X, Y , Z, 200Hz / g )

      Response time

      ≤2 ms

      Dielectric strength / RF degree

      EN 50081–1; EN 50082–1; IEC 61000–4–3

      Pressure connection

      See product selection table and process connecting drawing (may be    defined by the customer).

      Electrical wiring connection

      See product selection table and process connecting drawing (may be    defined by the customer).

      Port and Enclosure

      Stainless steel 1Cr18Ni9Ti

      O-ring

      Fluorubber

      Sensor Membrane

      Stainless steel 316L 

      Resolution

      Infinite small    (theoretical) 1 / 100000 (general)  

      Product selection

      HM20 

      General -    type pressure transducer

       

      Guideline of Selection

      High - accuracy Pressure Sensor

       

      Pressure type

      Gauge pressure (G, may not be indicated); Absolute    pressure (A)

       

       

      Range

      (0 ~  X kPa or 0    ~ X MPa)

       

       

       

       

      Code

      Overall accuracy (linear + repeatability + lagging)

       

       

       

       

      1

       ± 0.4% FS

       

       

       

       

      2

       ± 0.25% FS

       

       

       

       

       

       

      Code

      Signal output

       

       

       

       

       

       

      A1

      4 ~ 20mA

       

       

       

       

       

       

      V1

      1 ~ 5V DC

       

       

       

       

       

       

      V2

      0 ~ 5V DC

       

       

       

       

       

       

      V3

      0.5 ~ 4.5V DC

       

       

       

       

       

       

       

       

      Code

      Additional functions

       

       

       

       

       

       

       

       

      F1

      M20 x 1.5 external thread

       

       

       

       

       

       

       

       

      F2

      G 1 / 4 external thread

       

       

       

       

       

       

       

       

      F3

      1 / 4 NPT external thread

       

       

       

       

       

       

       

       

      F4

      1 / 2 - 20 UNF - 2A

       

       

       

       

       

       

       

       

      F0

      Special

       

       

       

       

       

       

       

       

      W1

      Cable type (See Outline Profile Drawing I)

       

       

       

       

       

       

       

       

      W2

      Socket type (See Outline Profile Drawing II)

       

       

       

       

       

       

       

       

      L1

      3 1 / 2 LCD display

       

       

       

       

       

       

       

       

      L2

      3 1 / 2 LED display

       

       

       

       

       

       

       

       

      P

      Flushed membrane type

       

       

       

       

       

       

       

       

      E

      Intrinsically safe explosion - proof type

       

       

       

       

       

       

       

       

       

       

       

       

       

       

      HM20     ( 0 ~ 100

      kPa)

      — 1

      — A1

      — F1

      — L2     General-type pressure transducer

       

       

       


      Tips of Selection

      1. The medium measured shall be compatible with the material contacting with the product.
      2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
      3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.


      bottom-nav_01.png

      主要產品:
      HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |
      三级黄色日本三级欧美三级黄色片,西西人体做爱视频,免费人成视频在线播放,在线免费成年片A