      HM28 Sapphire Pressure Transducer

      Description

      HM28 sapphire pressure transducer adopts German HELM made high – accuracy sapphire pressure sensor and performs temperature and linear compensation through such high – patent technologies as specific signal extraction and peeling etc. The sapphire series is made up of mono – crystalline silicon insulated elements, without any lagging, fatigue, and creeping. Sapphire features very good elastic and insulation characteristics, without sensitivity to temperature change. Sapphire has very strong radiation immunity characteristics. Furthermore, silicon – sapphire semiconductor sensitive element will not occur P – N drifting. Therefore, HM28 series of product may widely used for such fields as airspace and aerospace, petroleum, chemical, metallurgical, electric power, marine, medical and pharmaceutical, protection of environment, and scientific research etc. to measure and control high – temperature gas, liquid, fluid, and colloid, which is ideal for measuring high – temperature medium.

      Features of Product

      ☆ Measuring range: -100KPa ~ 0 ~ 4KPa…100KPa…1MPa…260MPa

      ☆ Wide range of medium temperature: -60~+200℃

      ☆ High accuracy☆ Good stability: ≤ 0.1% FS / year

      ☆ Designed with disturbance immunity

      ☆ Good corrosive resistance: Titanium – sapphire membrane

      ☆ Intrinsically safe explosion – proof

      Application of Product

      ☆  Industrial site process pressure testing

      ☆  Power generation plane, nuclear power generation station, water conservancy, hydropower

      ☆  Airspace and aerospace field

      ☆  Marine and shipbuilding industry

      ☆  Petroleum and chemical industry

      ☆  Scientific research and laboratory calibration

      ☆  Food industry

      Details

      Measuring range

      -100KPa ~ 0 ~ 4KPa…100KPa…1MPa…260MPa

      Overloading capacity

      Two times of scale for    10MPa product, 1.5 times of scale for the others

      Type of pressure

      Gauge pressure,  absolute pressure

      Medium to be measured

      All kinds of high – and    low – temperature liquid and gas suitable for titanium alloy and stainless    steel

      Overall accuracy
                 (Linear, repeatability,    lagging)

       ± 0.1% FS

       ± 0.25% FS

       ± 0.4% FS

      Medium temperature

      -65~+150℃

      Ambient temperature

      -40~+85℃

      Compensating    temperature

      -40~+120℃

      Long – term stability

       ± 0.1% FS / year

      Zero point temperature    drifting

      Typical:  ± 0.015% FS / ℃

      Maximum:  ± 0.03% FS / ℃

      Sensitivity    temperature drifting

      Typical:  ± 0.015% FS / ℃

      Maximum:  ± 0.03% FS / ℃

      Thermal lagging

       ± 0.1% FS (typical)

       

      Range of power    supplying

      12 ~ 36V DC (    generally 24V DC)

      Signal output

      4~20mA / 1-5V DC / 0~5V DC / 0.5-4.5V DC

      Load resistance

      ≤(U - 12) / 0.02Ω

      Insulation resistance

      100MΩ, 500V DC

      Response time (10% ~ 90%)

      ≤2ms

      Enclosure protection    degree

      IP65 or IP67

      Explosion – proof    Class

      Ex ia II CT5

      Material of structure

      Membrane: Titanium / silicon    – sapphire

      Enclosure: 1Cr18Ni9Ti    stainless steel

      Weight

      Approx. 250g

      Product selection

      HM28

      Sapphire  Pressure Transducer

       

      Guideline of Selection

      Sapphire  Pressure Transducer 

       

      Type of pressure

      Gauge pressure (G, may not be indicated); absolute pressure (A)

       

       

      Range

      Measuring Range

       

       

      0 ~ X KPa or 0 ~ X MPa

       

       

       

       

       

      Code

      Overall accuracy (linear + repeatability + lagging)

       

       

       

       

       

      1

       ± 0.4% FS

       

       

       

       

       

      2

       ± 0.25% FS

       

       

       

       

       

      3

       ± 0.1% FS

       

       

       

       

       

       

       

      Code

      Signal Output (Standard power supply of energization

       

       

       

       

       

       

       

      A1

      4 ~ 20mA (12 ~ 36V DC)

       

       

       

       

       

       

       

      V1

      1 ~ 5V DC (12 ~ 36V DC)

       

       

       

       

       

       

       

      V2

      0 ~ 5V DC (12 ~ 36V DC)

       

       

       

       

       

       

       

      V3

      0.5 ~ 4.5V DC (12 ~ 36V DC)

       

       

       

       

       

       

       

       

       

      Code 

      Additional functions

       

       

       

       

       

       

       

       

       

      F1

      M20 x 1.5 external thread

       

       

       

       

       

       

       

       

       

      F2

      G 1 / 4 external thread

       

       

       

       

       

       

       

       

       

      F0

      Special

       

       

       

       

       

       

       

       

       

      W1

      Cable type (IP67, 2m)

       

       

       

       

       

       

       

       

       

      W2

      Socket type (IP65, DIN 43650)

       

       

       

       

       

       

       

       

       

      P

      Flushed membrane type

       

       

       

       

       

       

       

       

       

      E

      Intrinsically safe explosion - proof type Ex ia II CT5

       

       

       

       

       

       

       

       

       

       

       

       

      HM28   A( 0 ~ 1.0MPa)

       

      — 2

      — A1

      — F1

      — W1 -P Sapphire  Pressure    Transducer 


      Tips of Selection

      1. The medium to be measured shall be compatible with the material contacting with the product.
      2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
      3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.


      bottom-nav_01.png

      主要產品:
      HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |
      三级黄色日本三级欧美三级黄色片,西西人体做爱视频,免费人成视频在线播放,在线免费成年片A