      HM26 Ceramic Capacitor Pressure Transducer

      Description

      HM26 ceramic capacitor pressure transducer adopts internationally advanced ceramic capacitor sensor, supported with high–accuracy electronic elements, and assembling with strict process. It adopts dry pressure measuring technology without intermediate liquid, thick membrane electronic technology, SMT (surface mount technology) and PFM signal transferring technology to fully play a role of technical advantages for ceramic capacitor sensor so as to make that the pressure transducer features excellent technical performance. It features strong anti–overloading and anti–impact capacity, high stability, and very high accuracy of measurement. This series of product may widely be used for such industrial fields as petroleum, chemical, metallurgical, electric power, pharmaceutical, and food etc.

      Features of Product

      ☆ Strong anti – overloading and anti – impact capacity, with over pressure up to several dozens to hundred times of scale 

      ☆ Adoption of imported ceramic capacitor sensor, with strong signal output, high comprehensive accuracy, and good stability 

      ☆Small temperature drifting due to without intermediate liquid for measuring element 

      ☆ Wide range of pressure, from micro pressure 0.5kPa to high pressure 100MPa, with optional combined pressure with positive and negative pressure 

      ☆ Pure ceramic substrate will not result process pollution. It applies to food and medical industrial. 

      ☆ Strong disturbance immunity, water – proof, dust – proof, vibration – proof, explosion – proof, and corrosion – proof. 

      ☆ Intrinsically safe explosion – proof, with explosion – proof Class Ex ia II CT5

      Application of Product

      Details


           Measuring range

      -100KPa ~ 0 ~ 5KPA…100MPa

      Overloading capacity

      3 ~ 100 times of    maximum rated pressure (the smaller scale, the bigger over pressure times

      Type of pressure

      Gauge pressure,  absolute pressure

      Medium to be measured

      Corrosive liquid, gas,    and vapor (the medium compatible with AL2O3  and 1Cr18Ni9N)

      Overall accuracy
           Non - linear, repeatability,    lagging

       ± 0.1% FS

       ± 0.25% FS

       ± 0.4% FS

      Medium temperature

      -40~+125℃

       

      Ambient temperature

      -40~+85℃

       

      Compensating    temperature

      -20~+80℃

       

      Long – term stability

       ± 0.1% FS / year

      Zero point temperature    drifting

       ± 0.02% FS / ℃

      Sensitivity    temperature drifting

       ± 0.02% FS / ℃

      Range of power    supplying

      12 ~ 36V DC (    generally 24V DC)

      Signal output

      4~20mA / 1-5V DC / 0~5V DC

      Load resistance

      ≤(U - 12) / 0.02Ω

      Material of structure

      Membrane: AL2O3  ceramic

      Enclosure: Cast    aluminum with low copper  content

      Connecting material:    1Cr18Ni9N

      Sealing structure: NBR,    PTFE or Fluorubber

      Safe explosion – proof

      Ex ia II CT5

      Enclosure protection    degree

      Plug type (IP65);    cable type (IP67)

      Response time (10% ~ 90%)

      ≤1ms

      Weight

      Approx. 500g

      Thermal lagging

       ± 0.01% FS (typical)

      Tolerance of vibration

      ≤ ± 0.01% FS(Axles X, Y,    and Z, 200Hz / g)

      Product selection

      HM26

      Ceramic Capacitor Pressure Transducer

       

      Guideline of Selection

      Ceramic    Capacitor Pressure Transducer

       

      Type of pressure

      Gauge pressure (G, may not be indicated); absolute pressure (A), combined    pressure with positive and negative pressure (F)

       

       

      Range

      Measuring Range

       

       

      0 ~ X KPa or 0 ~ X MPa

       

       

       

       

       

      Code

      Overall accuracy (linear + repeatability + lagging)

       

       

       

       

       

      1

       ± 0.4% FS

       

       

       

       

       

      2

       ± 0.25% FS

       

       

       

       

       

      3

       ± 0.1% FS

       

       

       

       

       

       

       

      Code

      Signal Output (Standard power supply of energization

       

       

       

       

       

       

       

      A1

      4 ~ 20mA (12 ~ 36V DC)

       

       

       

       

       

       

       

      V1

      1 ~ 5V DC (12 ~ 36V DC)

       

       

       

       

       

       

       

      V2

      0 ~ 5V DC (12 ~ 36V DC)

       

       

       

       

       

       

       

      V3

      0.5 ~ 4.5V DC (12 ~ 36V DC)

       

       

       

       

       

       

       

       

       

      Code 

      Additional functions

       

       

       

       

       

       

       

       

       

      F1

      M20 x 1.5 external thread

       

       

       

       

       

       

       

       

       

      F2

      G 1 / 4 external thread

       

       

       

       

       

       

       

       

       

      F0

      Special

       

       

       

       

       

       

       

       

       

      B1

      Stainless steel structure

       

       

       

       

       

       

       

       

       

      B2

      PMP 133 aluminum alloy structure ( E + H)

       

       

       

       

       

       

       

       

       

      P

      Flushed membrane type

       

       

       

       

       

       

       

       

       

      E

      Intrinsically safe explosion - proof type Ex ia II CT5

       

       

       

       

       

       

       

       

       

       

       

       

      HM26 G( 0 ~    10KPa)  

       

      — 1

      — A1

      — F1

      — B1  -E Ceramic Capacitor    Pressure Transducer


      Tips of Selection

      1. The medium to be measured shall be compatible with the material contacting with the product.
      2. The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.
      3. Please contact us in case of the other special requirements and clearly indicate them when placing an order.


      bottom-nav_01.png

      主要產品:
      HM10 High - accuracy Pressure Sensor |HM31 Differential Pressure Transducer |HM20 General - type Pressure Transducer Description |HM22 High - accuracy Pressure Transducer |HM23Y Special Pressure Transducer for Oilfield and Mining Well |HM27 Vacuum / Absolute Pressure Transducer |HM29 Digital ? Intellectual Pressure / Differential Pressure Transducer |HM50 Anti - corrosive Pressure Transducer |HM60 Anti - explosive Pressure Transducer |HM70 Hygienic Flat - membrane Pressure Transducer |HM80 High - temperature Pressure Transducer |HM90 High - frequency Dynamic Pressure Transducer |HM91 Micro Pressure Sensor and Transducer |